What changed
The standard is ANSI Z21.10.1, adopted by manufacturers with the US Consumer Product Safety Commission. Heaters built to it are called FVIR (flammable vapor ignition resistant). The common design seals the combustion chamber and lets air in only through a flame arrestor plate at the bottom, so vapor that drifts in burns inside without flashing back to the room.
It came in by size and type:
| Heaters | Built on or after |
|---|---|
| Atmospheric gas tanks of 30, 40 and 50 gallons | 1 July 2003 |
| Power-vented models of those sizes | 1 July 2004 |
| Other residential gas tanks | 1 July 2005 (one manufacturer cites 2007 for the last phase) |
Why it matters for an old heater
The rule doesn't require replacing a working pre-2003 heater. But a gas tank in a garage, next to a mower or a gas can, is the case the rule was written for. If yours was built before the cut-off, keep fuel and solvents well away from it and plan its replacement.
Telling a pre-2003 heater apart
- An open burner you can see through a removable access cover is older. FVIR heaters have a sealed inner door and usually a sight glass.
- On Bradford White heaters, whose year letters repeat every 20 years, this is the quickest way to choose between, say, 1987 and 2007.
- The manufacture date from the serial settles it on every other brand.